All gas entering the export pipeline will be expected to meet the following Entry Specification.
Gas Condition |
Cricondenbar , 106 bara As calculated by the Peng Robinson equation of state or such alternative method as may be agreed from time to time. |
| Pressure | < 163.8 barg |
| Temperature | -5°C to 35°C |
| Water Content | < 24 Kg per Mscm |
| H2S content | < 2.3 ppm |
| Total Sulphur Content | < 15 ppm expressed as H2S |
| CO2 Content | < 3.8% mole |
| O2 Content | < 7.5 ppm |
| Mercury | Maximum mercury content of 0.01 microgrammes per StandardCubic Metre, unless otherwise agreed. |
| Mercaptans | < 1.0 ppm Vol |
Natural Gas shall be commercially free from objectionable odours and from materials and dust or other solid or fluid matter, waxes, gums and gum forming constituents which might cause injury to, or interference with, the proper operation of the lines, meters, regulators or other appliances or facilities through which it flows.
No chemicals or other substances may be introduced by any means into the Natural Gas, which might be carried over into the Pipeline without the prior agreement of SIRGE Owners, such agreement not to be unreasonably withheld.
Natural Gas must be capable of being processed to meet National Grid Gas redelivery specification on Wobbe Index, Incomplete Combustion Factor, and Soot Index.
The above specification may be subject to change in the future as a result of different requirements from regulators, or governmental authorities, not within the control of the SIRGE Owners.